Introduction
Surge generators can be used to generate impulse of exponential shapes to perform high energy surge tests. The system can output combination wave (open circuit voltage 1.2/50us & short circuit current 8/20us, open circuit voltage10/700us & short circuit current 5/300us). With additional impulse modules, it can output 10/350us and 8/20us.
Applications
Test Class II or Class III SPD, and electronic appliances according to IEC 61000-4-5, IEC 61643-11,UL1449-2006
Technical SpecificationÂ
Model No |
Open circuit voltage waveform 1.2/50us |
Short circuit current Waveform 8/20us |
Output Impedance |
Impulse repetition |
CWG6 |
1~6kV |
0.5~3kA |
2Ohm |
3 pulses/minute |
CWG10 |
1~10kV |
0.5~5kA |
2Ohm |
2 pulses/minute |
CWG20 |
1~20kV |
1~10 kA |
2Ohm |
2 pulses/minute |
CWG30 |
1~30kV |
1.5~15kA |
2Ohm |
2 pulses/minute |
Optional
Different impulse modules for your choice
Impulse module no |
Output waveform |
Output range |
Output Impedance |
Impulse repetition |
JXIM-01 |
Combination waveform 10/700us
|
1~10kV |
40Ohm |
2 pulses/minute |
Combination waveform 5/300us |
25~250A |
|||
JXIM-02 |
10/350us |
1~5kA |
12Ohm |
2 pulses/minute |
JXIM-03 |
10/1000us |
75~375A |
37Ohm |
2 pulses/minute |
JXIM-04 |
8/20us |
5~30kA |
0.5Ohm |
2 pulses/minute |
AC or DC power source for operating duty test
Coupling/Decoupling network
![]() |
SAN MEN XIAN SHI XUAN ELECTRIC CO., LTD.
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Ltd. |